Search results will appear here

ACW

  • REACH
  • RoHS
  • CE
ACW
ACW Cross

Application

These are power train cables for automobiles. These are used in wire harness of low-tension engine compartment circuits for automobiles

Max. Operating Temperature

150°C

Cable Construction

Bare or annealed tinned copper

TPE-E (Thermoplastic Elastomer)

Packing

Available in 100 mtrs. Longer length available in spools.

Cabel Design Parameters

Nom.
Cross-Section
(mm²)
No. of
Strands
Max. Strand
Diameter (mm)
Max. Conductor
Diameter (mm)
Max. DC
Conductor
Resistance
at 20°C (Ω/km)
Nominal
Insulation
Thickness (mm)
Overall Diameter (mm)
Min.Max.
0.3570.260.952.00.251.21.4
0.50190.201.037.10.301.41.6
0.75190.241.2024.70.351.71.9
1.0190.261.3518.50.381.92.1
1.5300.261.712.70.352.22.4
2.5500.262.27.60.402.73.0
4.0560.312.754.70.453.43.7
6.0840.313.33.10.504.04.3

*Note:

  • Tinned copper conductor can be provided on request.