A2XFY/2XFY, A2XWY/2XWY-4 CORE

  • REACH
  • RoHS
A2XFY/2XFY-A2XWY/2XWY-4 CORE Wire
A2XFY/2XFY-A2XWY/2XWY-4 CORE Cross

Cable Construction

1.1 kV (A.C) & 1.5 kV (D.C ) to Earth
4 cores AL / CU conductor, XLPE insulated, galvanised steel strip / wire armoured cables as per IS 7098 Part – 1.

Conductor: AL up to 10 Sq. mm conductor are solid Cl. 1 as per IS 8130. And above 10 Sq. mm conductor are stranded compacted shape Cl. 2 as per IS 8130 In CU 4 & 6 Sq. mm conductor are solid Cl. 1 or stranded Cl. 2 as per IS 8130. 10 Sq. mm conductor is stranded Cl. 2, round as per IS 8130. Above 10 Sq. mm conductor are stranded compacted shaped Cl. 2 as per IS 8130

Insulation: Crosslinked polyethylene (XLPE)

Core Color: Red, yellow, blue, black

Inner Sheath: PVC / PVC tape as per IS 7098 (P – 1)

Armouring: Single armouring of galvanised steel strip / wire

Outer Sheath: PVC Type ST – 2 as per IS 5831 (Option : FR Type / FRLS Type)

Cable Color: Black (Options : Any other color as per requirement)

Cable Design Parameters

While ordering, in addition to the part number the following details shall also be advised: Conductor Type (Aluminium or Copper) and Class of conductor (Cl. 1 or 2). Sheath Type – PVC Type ST – 2 (FR or FRLS).

Part
Number
Nominal
Cross
Sectional
Area
(Sq. mm)
Nominal
Thickness
of
Insulation
(mm)
Minimum
Thickness
of Inner
Sheath
(mm)
Armouring with flat strip (A2XFaY/ 2XFaY)Armouring with Round Wire (AYWaY/YWaY)
Nominal
Thickness of
Arm. Strip
(mm)
Minimum
Thickness of
Outer Sheath
(mm)
Approx.
Overall
Dia.
(mm)
Approx Net Wt.
of Cable (kg/km)
Nominal
Diameter
of Wire
(mm)
Minimum
Thickness of
Outer Sheath
(mm)
Approx.
Overall
Dia.
(mm)
Approx Net Wt.
of Cable (kg/km)
AL Cable
A2XFaY
CU Cable
2XFaY
AL Cable
AYWaY
CU Cable
YWaY
11220040000440.70.3N/AN/AN/AN/AN/A1.41.2418540640
11220040000660.70.3N/AN/AN/AN/AN/A1.41.2419590760
112200400010100.70.3N/AN/AN/AN/AN/A1.41.421655940
112200400016160.70.30.81.42070011001.61.4229201280
112200400025250.90.30.81.42490015001.61.42611851750
112200400035350.90.30.81.427110020001.61.42814202185
112200400050501.00.30.81.5630140025001.61.563217302830
112200400070701.10.40.81.5634180034002.01.563723753980
112200400095951.10.40.81.5637220044002.01.724028705130
1122004001201201.20.50.81.7241270056002.01.884434756285
1122004001501501.40.50.81.8846320068002.52.044944807980
1122004001851851.60.50.82.0451390083002.52.25451859680
1122004002402401.70.60.82.20574850105002.52.3665638511985
1122004003003001.80.70.82.36635850130003.22.5268828015385
1122004004004002.00.70.82.68717320170003.22.8476998519480
1122004005005002.20.70.82.84799000210004.03.00861348024985
1122004006306302.40.70.83.008811000270004.03.00941597530485
  • For conductor and resistance refer table no. 16-1
  • For capacitances, reactance, short circuit rating refer table no. 16-5, 16-6 and 16-7
  • For current rating refer table no. 16-4