Search results will appear here

JZ-YCY BK 0.6/1.0 KV

  • REACH
  • RoHS
  • CE
JZ-YCY BK 0.6/1.0 KV
JZ-YCY BK 0.6/1.0 KV Cross

Application

Wiring cable in tool machinery, conveyor belts and production lines, plant engineering, Industrial machinery, air conditioning, steel production plants and rolling mills. The dense coverage of copper screening offers EMI compliance.

Standard

Adapted to DIN VDE 0262/12.95 and 0281 Part 13 with insulation thickness for 1 kV type.

Technical Data

Nominal Voltage: UO / U 0.6 / 1kV

Insulation Resistance: Min. 20 GΩ x cm

Temperature Range: Flexing -5°C to +70°C. Fixed installation -30°C to +70°C

Minimum Bending Radius: Flexing 20 x cable ø. Fixed installation 6 x cable ø

Test Voltage: 4000V

Breakdown Voltage: Min. 8000V

Cable Construction

Bare copper, fine wire conductors, to EN 60228 Cl.5

Core insulation of special PVC TI2, EN 50363-3.

Black Core with continuous white numbering to DIN VDE 0293.

Green/yellow earth core in outer layer (3 cores and above).

Cores stranded in layers with optimal lay-length.

PVC inner jacket, Black color.

Tinned copper, braided screen, approx 85% coverage

Special PVC outer sheath TM2, to EN 50363-4.1.

Colour Black (RAL 9005).

Properties

PVC self-extinguishing and flame retardant according to IEC 60332-1-2.

UV & weather resistant according to ASTM G 154.

Ozone resistant according to EN 50396.

Cabel Design Parameters

Part NumberNo. of Cores & Nominal
Cross Sectional Area (Sq. mm)
Approx. Cable
Diameter (mm)
Approx. Copper
Weight (kg/km)
Approx. Cable
Weight (kg/km)
0314002010752 x 0.7510.534.4150
0314003110753G 0.7510.940.9165
0314003010753 x 0.7510.940.9165
0314004110754G 0.7511.449.8185
0314004010754 x 0.7511.449.8185
0314005110755G 0.7512.160.0212
0314005010755 x 0.7512.160.0212
0314007110757G 0.7512.974.9247
0314007010757 x 0.7512.974.9247
03140121107512G 0.7515.8138.7389
03140120107512 x 0.7515.8138.7389
03140181107518G 0.7518.0185.5510
03140251107525G 0.7520.7243.4676
0314002000012 x 110.838.9161
0314003100013G 111.250.4181
0314003000013 x 111.250.4181
0314004100014G 111.859.4203
0314004000014 x 111.859.4203
0314005100015G 112.670.8235
0314007100017G 113.3107.3281
03140121000112G 116.4165.7433
03140181000118G 118.7233.9581
03140251000125G 121.6304.6771
0314002011052 x 1.511.850.3196
0314003111053G 1.512.362.4219
0314003011053 x 1.512.362.4219
0314004111054G 1.513.077.9252
0314004011054 x 1.513.077.9252
0314005111055G 1.513.993.4293
0314007111057G 1.515143.3366
03140121110512G 1.518.7222.3572
03140181110518G 1.521.8309785
03140251110525G 1.525.1411.11045
0314003112053G 2.513.591.9279
0314004112054G 2.514.6137.7349
0314005112055G 2.515.7158.8403
0314007112057G 2.517.0209493
03140121120512G 2.521.7333.7802
0314004100044G 417.0195483
0314005100045G 418.6235581
0314007100047G 420.1308704
0314004100064G 618.2269590
0314005100065G 619.7327706
0314007100067G 621.8437895
0314004100104G 1021.7425.5880
0314005100105G 1023.0521.91027
0314004100164G 1624.3666.51219
0314005100165G 1626.7820.11487
0314004100254G 2529.810071844
0314005100255G 2531.61242.12167
0314004100354G 3532.71384.42368
0314004100504G 5039.62032.23471
0314004100704G 7044.52824.24602
0314004100954G 9551.03706.26050
0314004101204G 12058.14650.37727

Note:

  • *G = With green/yellow earth core
  • x = Without green/yellow earth core
  • For current ratings refer table no. 12-1 & voltage drop refer table no. 12-2 of Appendix
  • For current ratings to DIN VDE 0298-4 refer table no. 12-3 of Appendix.