PROcess FIeld BUS

  • REACH
  • RoHS
  • CE
PROcess FIeld BUS Wire
PROcess FIeld BUS Cross

PROcess FIeld BUS is a standard for fieldbus communication in automation technology.
PROcess FIeld BUS links controller or control systems with decentralized field devices (sensors and actuators) via a single bus cable on
the field level. It also enables consistent data exchange with higher ranking communication systems. Consistency of PROcess FIeld
BUS is enabled by utilizing a single, standardized, application-independent communication protocol (named PROcess FIeld BUS DP),
which, without any difference, supports fieldbus solutions both in factory and process automation as well as in motion control and
safety-related tasks.
To ensure correct interaction between the numerous devices of an automation solution, the basic device functions and services must
match in regard to communication, functionality and industry sector solutions. This uniformity is achieved by means of “application
profiles” which refer to device families or special industry sector requirements, e.g. process automation (PA Devices), Motion Control
(PROFIdrive) or integration of HART devices.
PROcess FIeld BUS DP is in the central position and carries communication data between a controller and field devices, preferably in
Factory Automation (FA). PROcess FIeld BUS PA string is connected through a coupler or linking device to enable typical process
automation (PA) applications, e.g. in a hazardous environments. The controller is connected to PROcess FIeld NET as system bus and
interface to MES and ERP levels. PA segments can also be connected directly to PROcess FIeld NET using proxy technology.

Technical Data

Standard: Adapted to DIN 19245 & EN 50170

Operating Voltage: 250V (not for power installation)

Insulation Resistance : 5000 G x cm

Temperature Range: Flexing 12 x cable ø Fixed 6 x cable ø

Minimum Bending Radius: Flexing 12 x cable ø. Fixed installation 6 x cable ø

Test Voltage: 1500V

Flame Retardant: Complies ti IEC 60332-1-2

Cable Design Parameters

Bare copper stranded 7 wire conductor.

VariantsSizeConfigurationConstructionApplicationSheath
Colour
Approx.Cable
Dia. (mm)
Li2Y(St)CYv (TP)02Y(St)
CY DP
22 AWG x 1PR (0.32 Sq. mm)1/0.64 mmABC solid/Foam PE/PETP/AL. Mylar/ATC
Braid 65%/PVC Outer sheath
Fixed installation,
indoor usage
Violet8.0
02Y(St)
C11Y DP
22 AWG x 1PR (0.32 Sq. mm)1/0.64 mmABC solid/Foam PE/PETP/AL. Mylar/ATC
Braid 65%/PUR Outer sheath
Fixed installation,
Industrial Area
Black8.0
02Y(St)CY DP
Armoured
22 AWG x 1PR (0.32 Sq. mm)1/0.64 mmABC solid/Foam PE/PETP/AL. Mylar/ATC
Braid 65%/PVC Inner sheath/GI armour
wires/PVC Outer sheath
Direct BurialBlack (Outer)
Inner (Violet)
13.0
PROcess FIeld BUS PA02Y(St)CY
PA Solid
18 AWG x 1PR (0.8 Sq. mm) 1/1.02 mm
(1/18 AWG)
ABC solid/Foam PE/PETP/AL.
Mylar/ATC Braid 65%/PVC Outer sheath
Fixed installation,
indoor usage
Blue9.2
02Y(St)CY
PA Armoured
18 AWG x 1PR (0.8 Sq. mm)1/1.02 mm
(1/18 AWG)
ABC solid/Foam PE/PETP/AL. Mylar/
ATC Braid 65%/PVC Inner sheath/
GI armour wires/PVC Outer sheath
Direct BurialBlack (Outer)
Inner (Blue)
14.0

Electrical Parameters

PROcess FIeld BUS DP:

Conductor Resistance (Loop) at 20°C: 110 /km (Max.)

Mutual Capacitance: 35 nf/km (Max.)

Inductance: 0.65 mH/km (Nom.)

FrequencyCharacteristic
Impedance (Ω)
Attenuation
(dB/100m)
9.6 kHz270 ± 27≤ 0.25
38.4 kHz185 ± 18.5≤ 0.40
4 MHz150 ± 15≤ 2.2
16 MHz150 ± 15≤ 4.2

PROcess FIeld BUS PA: :

Conductor Resistance (Loop) at 20°C: 44 /km (Max.)

Mutual Capacitance : 55 nf/km (Max.)

Characteristic Impedance @ 31.25 kHz: 100 ± 15

Attenuation @ 39 Khz: ≤ 3 dB/km

Inductance: 0.65 mH/km (Nom.)

Baud Rate
(kbit/s)
Segment Length
(Meters)
Segment Length
(Feet)
9.612003940
19.212003940
45.4512003940
93.7512003940
187.510003280
5004001310
1500200656
3000100328
6000100328
12000100328

More Variants Available

PROcess FIeld BUS: DP and PA for flexible applications

PROcess FIeld BUS: DP and PA with steel braid

Halogen free variant with Low Smoke Zero Halogen (LSZH) outer sheath.:

Note :

  • HART = Highway Addressable Remote Transducer
  • DP = Decentralized Peripherals
  • PA = Process Automation