For power circuits in machine cabling power circuits for electrical equipments used in automation engineering. In dry damp or wet interiors with normal mechanical stress conditions for outdoor usage within the permitted range of temperature.

Technical Data

Standard: Adapted to DIN VDE 0250 / 0281 / 0282

Nominal Voltage : Uo / U 600 / 1000V

Insulation Resistance: Min. 20 GΩ x cm

Temperature Range: Flexing -40°C to +70°C

Fixed Installation: -50°C to +70°C

Minimum Bending Radius: Flexing 5 x cable ø. Fixed installation 3 x cable ø

Test Voltage: 4000V

Cable construction

Bare copper, fine wire conductors according to EN 60228 Cl. 6.

TPE core insulation.

Black coloured with white numbers acc to VDE 0293.

Cores are twisted together with shorter lay length.

Non woven wrapping.

Outer sheath : PUR grey (RAL 7001).

Properties

  • Flame retardant according to EN 60332-1-2.
  • Halogen free.
  • Oil resistant.
  • Low adhesive surface.
  • UV resistant to ASTM G 154.

Cable Design Parameters

Part NumberNo. of Cores & Nominal
Cross Sectional Area
(Sq. mm)
Approx. Cable
Diameter (mm)
Approx. Copper
Weight (kg/km)
Approx. Cable
Weight (kg/km)
0411004111054 G 1.510.051.2132
0411004112054 G 2.511.985.8189
0411004100044 G 413.7138.3268
0411004100064 G 615.1204.3374
0411004100104 G 1019.6358.5609
0411004100164 G 1622.8580.2896
0411005111055 G 1.511.264.0161
0411005112055 G 2.513.3107.2233
0411005100045 G 415.2172.9330
0411005100065 G 616.8255.3461
0411005100165 G 1625.5725.21106
0411005100255 G 2530.811301699

Note :

  • * G = With green/yellow earth core