Search results will appear here

UL 1007

  • REACH
  • RoHS
  • CE
UL 1007 Wire
UL 1007 Cross

Application

These cables are used for internal wiring of switchboards, electronic and electrical equipment, e. g. households, radio of televisions, monitor and control desks.

Technical Data

Standard: UL – Std. 758 , CSA C 22.2 No. 210

Nominal Voltage: 300V

Test Voltage: 2000V Test Voltage (Spark Test)

AWG 26-20: 4kV, AWG 10 -18 : 5kV

Temperature Range: Flexible -5°C to +80°C. Fixed installation -20°C to + 80°C CSA – AWM I A/B

Bending Radius: Flexing 10 x cable ø. Fixed installation 5 x cable ø

Cable Construction

Annealed plain or tinned stranded copper conductor.
PVC – core insulation according to UL – Standard 1581, Class 43 Tab. 50.182, heat and damp resistant.

Properties

  • Conditionally resistant to oils, solvents, acids and dyes.
  • PVC self – extinguishing and flame retardant, test method to UL VW-1 and CSA FT 1 / FT 2

Cable Design Parameters

Kindly complete the part numbers for these cables by adding the suffix (in place of ‘xx’) for the insulation colour required: 01 – green, 02 – black, 03 – red, 04 – blue, 05 – yellow, 06 – green/yellow, 07 – white, 08 -Violet, 09 – brown, 10 – orange, 11 – pink, 12 – grey, 13 – light blue.

Part NumberAWG No.No. of Cores and
Nominal Cross Sectional
(Sq. mm)
Approx. Cable
Diameter (mm)
Approx. Copper
Weight (kg/km)
Approx. Cable
Weight (kg/km)
06030101xx30261 x 0.141.31.43.0
06030102xx30241 x 0.211.52.14.3
06030103xx30221 x 0.331.63.55.8
06030104xx30201 x 0.521.95.28.0
06030105xx30181 x 0.822.28.312.0
06030106xx30161 x 1.322.513.518.4