Search results will appear here

UL 3289/3321/3173/3271/3344 XLPE CABLE

  • REACH
  • RoHS
  • CE
UL 3289/3321/3173/3271/3344 XLPE CABLE Wire
UL 3289/3321/3173/3271/3344 XLPE CABLE Cross

Application

These cables have excellent resistance to abrasion, deformation, cut-through and chemical attack. This wire is widely used in appliances, transformers, electrical heating, motors, ballast, lighting and cooking equipment. Suitable for use as Appliance Wiring Material (AWM), coil leads and as Class B IEEE 130°C Class Motor Leads. Economical replacement for silicone rubber/glass braid insulated wire and cable.

Technical Data

Standard: UL – Std. 758. Complies to CSA No. 22.2 210 and 127

Nominal Voltage: 600V

Test Voltage (Spark Test):

AWG 22 and 20: 5kV

AWG 18 to 10: 6kV

≥ AWG 8: 7.5kV

Temperature Range: Flexible -5°C to +150°C. Fixed installation -50°C to +150°C

Temperature at Conductor: Max. UL : +150°C

Bending Radius: Approx. 5 x cable ø

Cable Construction

  • Annealed plain or tinned stranded copper conductor.
  • XLPE insulation according to UL- Std. 1581 Table 50.232, Complies to CSA No. 22.2 210 and 127.

Properties

  • PVC self – extinguishing and flame retardant, test method to FT 2

Cable Design Parameters

AWGMetric
Cross Section
Area (Sq. mm)
No. of
Strands/Strand Dia.
(mm)
Max. DC Conductor
Resistance for
ABC @ 20°C (Ω/km)
Max. DC Conductor
Resistance for
ATC @ 20°C (Ω/km)
Insulation
Thickness
(mm)
Nominal Cable
Diameter (mm)
210.5016/0.243.646.90.7622.4
190.7524/0.227.429.10.7622.6
181.0032/0.221.823.20.7622.8
161.5030/0.2513.714.60.7623.1
142.5050/0.258.628.960.7623.5
124.0056/0.35.435.640.7624.0
106.0084/0.33.4093.5460.7624.6
810.00140/0.32.1442.231.1436.1
616.00126/0.41.3481.4031.5247.9
425.00196/0.40.84810.8821.5249.1
235.00276/0.40.53350.55481.52410.7
150.00296/0.40.4230.43982.03212.8
2/070.00360/0.50.2660.27662.03214.8
3/095.00480/0.50.2110.21942.03216.2
4/0120.00608/0.50.16730.17222.03217.7

Kindly complete the part numbers for these cables by adding the suffix (in place of ‘xx’) for the insulation colour required: 01 – green, 02 – black, 03 – red, 04 – blue, 05 – yellow, 06 – green/yellow, 07 – white, 08 -violet, 09 – brown, 10 – orange, 11 – pink, 12 – grey, 13 – light blue Kindly complete the part numbers by adding the suffix (in place of ‘c’) for the conductor type required: 0 = annealed bare copper (ABC), 1 = annealed tinned copper (ATC)

AWGMetric
Cross Section
Area (Sq. mm)
Part Number
UL 3289UL 3321UL 3173UL 3271UL 3344
210.506090101xx9c06090116xx9c06090131xx9c06090146xx9c06090161xx9c
190.7506090102xx9c06090117xx9c06090132xx9c06090147xx9c06090162xx9c
181.0006090103xx9c06090118xx9c06090133xx9c06090148xx9c06090163xx9c
161.506090104xx9c06090119xx9c06090134xx9c06090149xx9c06090164xx9c
142.506090105xx9c06090120xx9c06090135xx9c06090150xx9c06090165xx9c
124.0006090106xx9c06090121xx9c06090136xx9c06090151xx9c06090166xx9c
106.0006090107xx9c06090122xx9c06090137xx9c06090152xx9c06090167xx9c
810.0006090108xx9c06090123xx9c06090138xx9c06090153xx9c06090168xx9c
616.0006090109xx9c06090124xx9c06090139xx9c06090154xx9c06090169xx9c
425.0006090110xx9c06090125xx9c06090140xx9c06090155xx9c06090170xx9c
235.0006090111xx9c06090126xx9c06090141xx9c06090156xx9c06090171xx9c
150.0006090112xx9c06090127xx9c06090142xx9c06090157xx9c06090172xx9c
2/070.0006090113xx9c06090128xx9c06090143xx9c06090158xx9c06090173xx9c
3/095.0006090114xx9c06090129xx9c06090144xx9c06090159xx9c06090174xx9c
4/0120.0006090115xx9c06090130xx9c06090145xx9c06090160xx9c06090175xx9c